Tip 1: In Drop test, it related with hardware power layout. Please MUST support the 500mA loads. (VBUS connects 10 ohm to GND.)
Tip2: In Signal quality Test, please check with 0, 1.8, 3, 5M cables. If it's fail, please check the hardware circuit first.
Tip3: In Interoperability Test, the silence message is needed. And messages of hub and NOT support device MUST be different.
Embedded Host | Test Item |
Full Speed Test | Drop test |
Droop test | |
SRP test | |
Interoperability | |
Full Speed Downstream Signal Quality Test | |
High Speed Test | High Speed Signal Quality (EL_2,EL_3,EL_6,EL_7) |
Host Controller Packet Parameters (EL_21,EL_22, EL_23,EL_25,EL_55). | |
Host CHIRP Timing (EL_33,EL_34,EL_35) | |
Host Suspend/Resume Timing (EL_39,EL_41) | |
Device Test J/K,SE0_NAK (EL_8,EL_9) |